FAQ’s

Q: Can I operate the ORION’s ‘modem enable/disable’ pin directly from a microcontroller’s output?

Yes. The pin can be driven directly from a 5v or a 3v3 micro-controller output pin. 

  • Any voltage >0.9volts DC switches the ORION on.
  • Any voltage <0.9volts DC switches the ORION off.

This ORION connection pin is very useful when the ORION is being used in battery-operated installations where current consumption needs to be carefully managed.